26-08-2025
At SIW, our people are the driving force behind our success.Every wire we manufacture and every solution we deliver reflect the dedication, expertise, and collaborative spirit of the SIW family.Together, we create connections that strengthen industries and shape a better world.Miss Naiyana ThamnaoChief Human Resources Officer
19-08-2025
Steel Truss Bridge vs. Concrete Box Girder Bridge – What’s the Difference? 🌉Choosing the right bridge structure is not just about aesthetics — it's a decision about strength, lifespan, and long-term value.Steel Truss Bridge (Truss Bridge)Structural weight: Light, suitable for small foundationsSpan: Can be very long (100–500 m)Strength: Strong – resists both compression and tension using triangular truss to distribute forcesMaterial cost: Medium to high (custom-made, almost no repairs needed)Construction complexity: High – assembled from many partsMaintenance: Requires rust protection and frequent inspection of rivets or boltsConcrete Box Girder BridgeStructural Weight: Heavier than truss bridges but lighter than traditional solid beam bridges, while still offering high strengthSpan Length: Medium to long spans (40–200 m)Strength: Handles compressive, tensile, and torsional forces effectivelyMaterial Cost: Moderate to high (especially when custom-fabricated)Construction Complexity: Moderate to high – requires special formworkMaintenance: Minimal, though internal maintenance can be challenging💡 Quick Summary:Truss Bridge: Light, suitable for extra-long spans, good for areas with limited foundations — but needs rust careBox Girder Concrete Bridge: Strong, durable, ideal for large-scale and national infrastructure — with low maintenance
05-08-2025
SIW had the opportunity to engage in a discussion withAssoc. Prof. Dr. Suniti Supap,Head of the Department of Civil and Environmental Engineering,andAssoc. Prof. Dr. Panawat Joyklad,from the Faculty of Engineering, Srinakharinwirot University (SWU),to explore potential collaboration in curriculum development and practical material testing.This initiative aims to bridge classroom knowledge with real-world industrial applications,creating mutual benefits in both academic advancement and the practical skill development of civil engineering students.
29-07-2025
At SIW, quality is not just a standard — it's our promise.We take pride in producing high-quality products tailored to meet our customers’ unique needs.With a strong focus on precision and rigorous quality control, we ensure that our products empower you to build with confidence and excellence.Mr. Worachoke ChavengpojHead of Department-Production
21-07-2025
More than a manufacturer — we are the standard the world trusts.SIW is a leading producer of PC Strand and PC Wire, trusted by global-scale projects.We go beyond products — focusing on quality, safety, and service excellence.That’s why SIW holds the No.1 market share in Thailand’s prestressed steel wire industry.
08-07-2025
SIW plays a key role in supplying high-quality materials for Bang Khun Thian – Ban Phaeo Expressway Project, which is currently under construction. We are committed to using certified raw materials and products, backed by stringent quality control processes, to ensure the expressway’s structure is strong, durable, and safe—meeting all project requirements. Additionally, SIW works closely with the project team to ensure smooth and timely deliveries, fully supporting the project’s success.
07-07-2025
A Closer Look at “Thai vs Japanese Structures” – Essential Knowledge for Earthquake-Resistant Design.🎁 Special Giveaway!Like + Share this post for a chance to win exciting prizes!📍 [Live Session]🕑 Starts at 2:00 PM | Tuesday, July 8, 2025Watch live on: Facebook: https://www.facebook.com/share/v/1Awmf5PaeK/ YouTube: https://youtube.com/live/P3cKiPsbqo8?feature=share Join the conversation and dive into construction standards with earthquake engineering expert:Professor Dr. Panuwat JoykladDepartment of Civil and Environmental Engineering,Faculty of Engineering, Srinakharinwirot University #SIW #EarthquakeResistantStructures
01-07-2025
What is "Fatigue"?Why Must Strong Structures Pass This Test?In engineering, a material being strong doesn’t always mean it’s durable.What’s more challenging than tensile strength is repeated loading, also known as Fatigue.What is Fatigue?Fatigue is the weakening of a material caused by repeated loading and unloading.For example, steel wires used in prestressed concrete, piles, or bridges may not break from a single force.But after tens or hundreds of thousands of repeated stresses, the material becomes "fatigued" — and can fail without warning.Examples of Fatigue-Related Failures:Bridge cables snapping after just a few years of useStructural collapse due to continuous vibrationsDamage invisible to the naked eyeWhy Perform Fatigue Testing at SIW-Testing Service Center?1. Internationally Certified StandardsSIW operates the only wire testing lab in Thailand certified for Fatigue Testing by NATA (Australia’s national lab accreditation body).This guarantees that all equipment and processes meet strict international standards.2. Real Testing — Beyond TheoryWe simulate repeated stress cycles to determine how many times your wire can withstand force before failure.You’ll receive detailed reports with clear graphs, backed by advanced tools and expert analysis.3. Supporting Nation-Level ConstructionSIW supports major infrastructure projects—expressways, bridges, rail systems—where high-performance wire is critical.Fatigue testing is a key step before the wire is ever used in the field.
25-06-2025
What are the applications of 7-wire PC Strand?1. LNG Tank – Liquefied Natural Gas Storage Tank2. Wind Tower – Wind Turbine Tower3. Nuclear Reactor Tank – Nuclear Reactor Containment Tank4. Bonded Post Tension Bridge – Bonded Post-Tensioning Bridge System5. Beam & Column – Beams and Columns6. Bridge Girder – Bridge Girders7. Plank Girder – Precast Floor Girders8. Concrete Pile – Concrete Piles9. Hollow Core Plank – Hollow Core Slabs10. Cement Silo – Cement Storage Silo11. Precast Segmentation Box – Precast Concrete Segment Box12. Water Treatment Tank – Water Treatment TankSIW's PC Strand has been tested and certified to meet global quality standards and certifications with sales in over 70 countries worldwide. Additionally, the product is environmentally conscious, using raw steel wire with a significant proportion of recycled materials.Diameter: 7.9 - 18 mmStandards: TIS 420-1997, AS/NZS 4672-2007, ASTM A416-2016, ASTM A416-2017, ASTM A886-2012, BS 5896-2012, prEN 10138-2012, JIS G 3536-2014, LNEC E 453-2020, XPA35-04503, MS 1138-4-2007, SNI 1154-2011, TSE 5680-1998, IS 14268-1995, GB/T 5224-2014, NBR 7483, UNE 36094-1997, SFS 1265-3, SS 212553-2013, NEN 3868, NBN I 10-003, UNI 7676-2016Contact us:Email: marketing@siw.co.thTel: (+66) 81-170-2571 hashtag#PCStrand
20-06-2025
ตอกย้ำความเป็นผู้นำ! การันตีด้วยมาตรฐานระดับโลกตลอด 30 ปีบนเส้นทางแห่งการเป็นผู้ผลิต "ลวดเหล็กกล้าอัดแรง" ชั้นนำ เรายึดมั่นในคุณภาพและความรับผิดชอบในทุกกระบวนการ ความทุ่มเทของเราได้รับการพิสูจน์ผ่านรางวัลและมาตรฐานอันทรงเกียรติมากมาย ซึ่งเป็นเครื่องยืนยันถึงความไว้วางใจจากทุกภาคส่วน ด้านอุตสาหกรรมสีเขียวและความยั่งยืน:- อุตสาหกรรมสีเขียว ระดับที่ 4 (วัฒนธรรมสีเขียว)- รางวัล CSR-DIW (พ.ศ. 2546 - 2567)- รางวัลธรรมาภิบาลสิ่งแวดล้อมและความปลอดภัย- มาตรฐานผลิตภัณฑ์อุตสาหกรรม: แนวทางเศรษฐกิจพอเพียงภาคอุตสาหกรรม (มอก. 9999) ด้านแรงงานและอาชีวอนามัย:- รางวัลสถานประกอบกิจการดีเด่นด้านแรงงานสัมพันธ์และสวัสดิการแรงงาน (พ.ศ. 2552 - 2567)- มาตรฐานแรงงานไทย (มรท. 8001-2546)- รางวัลสถานประกอบกิจการต้นแบบดีเด่นด้านความปลอดภัยฯ ด้านจรรยาบรรณและความโปร่งใส:- รางวัลประกาศเกียรติคุณจรรยาบรรณดีเด่น หอการค้าไทย (TCC BEST Awards)- รางวัลองค์กรโปร่งใส (NACC Integrity Awards)ความสำเร็จทั้งหมดนี้เกิดขึ้นได้เพราะการสนับสนุนจากลูกค้า คู่ค้า และความทุ่มเทของพนักงานทุกคน เราขอขอบคุณจากใจจริง และจะมุ่งมั่นพัฒนาองค์กรเพื่อสร้างสรรค์คุณค่าสู่สังคมและอุตสาหกรรมไทยอย่างยั่งยืนต่อไป
16-06-2025
High-Quality PC Strand for Nuclear ReactorsReliable under all conditions with superior standardsSIW’s PC strand has passed stress relaxation testing at elevated temperatures up to 40°C, compared to the industry standard testing typically conducted at room temperature (approximately 20°C).This ensures that SIW’s PC strand is well-suited for use in nuclear reactors, even under high-temperature conditions.✅ Proven performance under high-temperature and high-risk environments ✅ A trusted choice for international-level critical structures✅ Low carbon footprint and certified with an Environmental Product Declaration (EPD)
10-06-2025
Confidence in Every Wire. Strength in Every Strand.SIW’s Uncompromising Quality Control – For World-Class Steel Wire.Because steel wire isn’t just a piece of metal—it’s the backbone of every construction project. It must deliver the highest strength and safety standards. That’s why SIW pays attention to every detail in the manufacturing process, ensuring each batch meets the highest expectations for quality and performance.✅ Tensile Strength TestingEach wire undergoes standardized tensile strength tests to ensure it can withstand high tension without snapping or becoming brittle. This enhances the long-term durability and structural integrity of your project.✅ Diameter PrecisionEvery wire is manufactured to exact specifications, allowing for precise material calculations, easy assembly, and reduced waste on-site.✅ Rust ProtectionCorrosion control is built into the production process, extending the life of your construction and protecting against premature degradation or failure.✅ Certified to Global StandardsSIW wire meets both national (TISI) and international (NATA, Australia) standards. Each batch comes with a full Quality Control Certificate—ready for use in any project with full traceability and peace of mind.SIW Steel Wire is trusted in major national projects across both public and private sectors, known for consistent quality and reliable service. Choose SIW’s thoroughly QC-tested wire for the strength and certainty your project—and future—deserve.
06-06-2025
How Is PC Wire Used Differently in Post-Tension vs Pre-Tension Systems?PC Wire (Prestressed Concrete Wire) is a crucial material used to strengthen prestressed concrete. It is commonly applied in two major systems: Pre-tension and Post-tension. While they use similar materials, the method of application and the advantages of each system are distinctly different. Let’s explore the differences🔹 Pre-Tension (Before Concrete Pouring)In this system, PC Wire is tensioned before the concrete is poured into the mold. Once the wire is stretched to the required force, concrete is poured over it. After the concrete sets and gains strength, the tension is released, and the wire tries to return to its original state, which compresses the concrete.Ideal for: Factory-made precast elements such as floor planks, hollow-core slabs, and concrete beamsAdvantages: Quality can be easily controlled in a factory settingLimitations: Requires large formwork and transportation of finished components to the site🔹Post-Tension (After Concrete Pouring)In this method, ducts or sheaths are placed inside the formwork before concrete pouring. Once the concrete is cured, PC Wire is threaded through the ducts, then tensioned and anchored at both ends. Finally, the ducts are filled with grout to protect the steel and bond it to the concrete.Ideal for: Large-scale projects such as high-rise buildings, bridges, and flat slab systemsAdvantages: More design flexibility, thinner structural elements, material efficiencyLimitations: Requires skilled labor and strict on-site quality control*Both systems have unique strengths and trade-offs. Choosing the right one depends on project type, budget, and engineering requirements.At SIW, we manufacture high-quality PC Wire for prestressed concrete applications in both pre-tension and post-tension systems. Our products are certified with TIS standards and trusted in over 70 countries worldwide.hashtag#SIW hashtag#PCwire hashtag#posttension hashtag#pretension
26-05-2025
Special Grade Earthquake-Resistant PC Strand - "A Safety Standard for Life Beyond Strength"In an earthquake situation, the very seconds when a structure begins to fail can determine life or death. Therefore, designing structures to delay "Collapse" becomes a critical factor in ensuring enough time for safe evacuation.At Siam Industrial Wire (SIW), we place great emphasis on every mechanical property of PC Strand, recognizing its importance as a key component in civil engineering design. Our special earthquake-resistant PC Strand is developed with a higher "Force Ratio" than standard products.• Force Ratio (the ratio between Breaking Load and Yield Load) in SIW’s PC Strand is higher than standard grades, meaning the steel does not fail immediately after reaching its yield point.• This allows the structure to withstand seismic forces longer, effectively "delaying" Collapse and giving occupants valuable time to evacuate safely.• Additionally, the increased "Plastic Deformation" of steel enabled by the high Force Ratio makes the product suitable for plasticity-based structural design, which emphasizes "Ductile Behavior".• And when exposed to seismic forces, this ductility causes serious and visible "Cracking" before total collapse occurs, serving as a warning sign that allows for timely intervention or evacuation.• It also helps reduce the risk of Nature Abrupt or sudden Collapse as plasticity-based design lowers the chance of instant concrete brittle failure — which in turn increases the likelihood of survival and reduces potential loss.SIW manufactures and exports special-grade PC Strand with a higher Force Ratio than standard requirements to Denmark, conforming to FprEN 10138-1&-3:2009 standards. These products are certified with the FI Marking of Denmark.At SIW, we are deeply aware of the impacts of natural disasters and the value of every life.
15-05-2025
“ผนังร้าวจากแผ่นดินไหวยังไม่พอ…ฝนตกยิ่งน้ำรั่วซึม” หลายพื้นที่เพิ่งเจอแรงสั่นสะเทือนจากแผ่นดินไหว แล้วก็เริ่มพบว่า “ผนังรั่วซึม” เมื่อฝนตกตามมา หากเจอแบบนี้ อย่าเพิ่งตกใจ เราขอแนะนำวิธีแก้เร่งด่วนเบื้องต้นที่คุณทำได้เอง: 1. หาต้นตอรอยร้าว – ส่องให้ดีว่ารั่วมาจุดไหน แนวร้าวแนวตั้ง/เฉียง หรือแค่ผิวปูน 2. ทำความสะอาดรอยร้าว – ใช้แปรงหรือผ้าชุบน้ำ เช็ดคราบฝุ่นและสิ่งสกปรก 3. อุดด้วยซิลิโคนหรือซีเมนต์กันซึม – แบบสำเร็จรูป หาซื้อได้ตามร้านวัสดุก่อสร้าง ใช้งานง่าย 4. ปิดทับด้วยเทปกันซึม/ฟิล์มกันน้ำ (ชั่วคราว) – ถ้าไม่มีเวลา ให้ปิดกันน้ำเข้าไว้ก่อน 5. หลีกเลี่ยงการทาสีหรือฉาบทับทันที – เพราะจะดักความชื้นไว้ ทำให้เชื้อราขึ้นง่าย แต่ทั้งหมดนี้เป็นแค่ “มาตรการชั่วคราว” เพื่อรอให้โครงสร้างนิ่งแล้วค่อยซ่อมถาวร โดยอาจต้องปรึกษาวิศวกรหรือตรวจสอบความปลอดภัยของโครงสร้างก่อน อย่าปล่อยให้รอยร้าวกลายเป็นปัญหาใหญ่ในอนาคต **ทั้งนี้ทั้งนั้นขึ้นอยู่กับขนาดรอยร้าว #รอยรั่วหลังแผ่นดินไหว #บ้านรั่วทำไงดี #กันซึมDIY #วิธีแก้น้ำซึมเร่งด่วน #ปลอดภัยไว้ก่อน
13-05-2025
Sustainability is not just our goal—it’s our responsibility.At SIW, we are committed to leading the steel industry toward a cleaner, smarter future. From reducing carbon emissions and ensuring zero wastewater discharge to integrating AI-driven efficiency and nurturing our team’s growth, every step we take is driven by a clear mission:Achieve Net Zero by 2050.Hear from our Managing Director, Chandrasekaran Srivatsan, on how we’re building a more sustainable tomorrow.hashtag#Sustainability hashtag#NetZero2050 hashtag#GreenSteel hashtag#AIforSustainability hashtag#SIW hashtag#EPD
We are relentless in our pursuit for excellence in product quality and innovation. We take pride in being able to anticipate your needs and provide tailored solutions for each of your requirements. We strive to exceed expectations.