PC Wire from SIW is manufactured using high-quality materials and advanced production technology to ensure exceptional strength, durability, and world-class standards. Certified under TIS 95, ASTM A421, JIS G3536, AS/NZS 4672, BS 5896, and pr EN 10138-2,our products meet diverse customer needs with various types — plain, indented, crimped, and spiral.
Each wire is designed to suit different applications and environments, ensuring superior performance and reliability. With SIW PC Wire, quality is guaranteed in every strand. Contact us through any channel today.
Contact: 081-170-2571
Line: @siwthailand
Website: www.siw.co.th
#SIW #SIWThailand #PCWire #PrestressedConcrete #HighQualitySteel
06-05-2025
SIW-Testing Service Center for Prestressed Steel Wire Quality TestingPerfect for manufacturers or users of PC Wire and PC Strand who require quality test results according to various standards. With over 30 years of expertise, SIW’s lab specializes in prestressed steel wire quality testing.Convenient, Fast, and Cost-effectiveISO/IEC 17025 certified by NATA (National Association of Testing Authorities, Australia)Detailed, Clear, and Traceable Reports at Every Step, with Analysis and Improvement SuggestionsModern Equipment with High Efficiency and Precision of Over 99.95%Flexible Testing Customization Based on Client Requirements, Including Specific TestsService Information:1. Fatigue Testing MachineBrand: Zwick Roell, Model: HA500Testing Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, BS 5896, LNEC E 542, LNEC E 453, ISO 15630 Part 3, TIS 95-2540, TIS 420-2540PC Wire: Maximum Load 500 kN, Sample Diameter 5 – 22 mmPC Strand: Maximum Load 500 kN, Sample Diameter 5 – 22 mmDeformed Bar: Maximum Load 500 kN, Sample Diameter 5 – 40 mm2. Relaxation Testing MachineTesting Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, ASTM A416/A416M, ASTM A421/A421M, ASTM A881, BS 5896, ISO 15630-3, JIS G3536, TIS 95-2540, TIS 420-2540PC Wire: Maximum Load 300 kN, Sample Diameter 4 – 9 mmPC Strand: Maximum Load 500 kN, Sample Diameter 9.3 – 18.0 mm
26-11-2025
At SIW, we are Thailand’s leading experts in construction wire with the lowest carbon emissions in the steel wire industry. With carbon emissions of only 1.84 kgCO2 eq., significantly lower than the industry average of 2.46 kgCO2 eq. Our commitment to sustainability is certified by the Thailand Greenhouse Gas Management Organization (TGO).Strengthen your construction projects with SIW wire, a product that is eco-friendly and professionally reduces environmental impact.#SIW #EcoFriendlySteel #CarbonReduction
26-08-2025
At SIW, our people are the driving force behind our success.Every wire we manufacture and every solution we deliver reflect the dedication, expertise, and collaborative spirit of the SIW family.Together, we create connections that strengthen industries and shape a better world.Miss Naiyana ThamnaoChief Human Resources Officer
24-08-2026
EP.1: What Is PC Strand?🏗️ Have you ever wondered what makes bridges and high-rise buildings so strong?The answer is PC Strand—a high-tensile steel strand that plays a vital role in prestressed concrete. It enables structures to withstand greater loads while enhancing their strength, durability, and service life.Because every strong structure begins with materials that meet recognized quality standards.
30-08-2024
Why Choose SIW - Testing Service Center for PC Wire and PC Strand Testing?✔️Convenient, Fast, and Cost-Effective✔️ISO/IEC 17025 Certified by NATA (National Association of Testing Authorities, Australia)✔️Modern, High-Efficiency Equipment with Over 99.95% Accuracy✔️Compliant with Standards of Over 70 Countries, Including TIS, ASTM, JIS, and MoreService Information:1. Fatigue Testing Machine-Brand: Zwick Roell, Model: HA500-Testing Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, BS 5896, LNEC E 542, LNEC E 453, ISO 15630 Part 3, TIS 95-2540, TIS 420-2540-PC Wire: Maximum Load Capacity of 500 kN, Supports Sample -Diameters of 5 – 22 mm-PC Strand: Maximum Load Capacity of 500 kN, Supports Sample -Diameters of 5 – 22 mm-Deformed Bar: Maximum Load Capacity of 500 kN, Supports Sample Diameters of 5 – 40 mmRelaxation Testing Machine2. Testing Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, ASTM A416/A416M, ASTM A421/A421M, ASTM A881, BS 5896, ISO 15630-3, JIS G3536, TIS 95-2540, TIS 420-2540-PC Wire: Maximum Load Capacity of 300 kN, Supports Sample Diameters of 4 – 9 mm-PC Strand: Maximum Load Capacity of 500 kN, Supports Sample Diameters of 9.3 – 18.0 mm Contact Us: >>Click<<
03-09-2025
SIW ranks 7th globally and is the only EPD-certified high-strength steel wire manufacturer in Southeast Asia. With a carbon emission value of only 2.19 kg CO₂ eq. per unit of PC StrandSIW supports green building, reduces carbon emissions, and saves energy —a step forward toward a more sustainable future.
07-08-2023
Surface corrosion and pitting corrosion differ in the following ways: Surface Corrosion: Surface corrosion refers to the corrosion that occurs on the surface of a metal, where the metal surface is not deeply eroded or penetrated by corrosion to the extent that it becomes pitted or significantly damaged. Pitting Corrosion: Pitting corrosion is corrosion that develops on the metal surface over an extended period, causing the metal surface to be deeply eroded and penetrated into the metal substrate. This leads to significant damage to the metal, rendering it unsuitable for use. Corrosion Mechanism:When a metal undergoes oxidation or is subjected to reduction, the corrosion process takes place, resulting in the erosion of the metal. Therefore, the primary goal of corrosion prevention is to inhibit the occurrence of oxidation reactions. The most resistant metals to corrosion are those with the highest positive electrode potentials, such as gold. Platinum, silver, and red gold also possess good resistance to corrosion due to their relatively high positive electrode potentials. On the other hand, other metals are more susceptible to oxidation, meaning they are more likely to corrode easily. An example of a commonly encountered and distinct corrosion process is the formation of rust on iron or the creation of iron oxide. Iron corrodes when there is the presence of oxygen and water. The corrosion process of iron is relatively complex and has unique characteristics. However, it is believed to involve critical steps, including: 1. Oxidation reaction occurs at a specific area on the iron surface, acting as the anode. This can be represented by the equation: Fe(s) Fe2+(aq) + 2e-2. Oxygen is reduced at another area of the iron surface, acting as the cathode. In the presence of water, the equation becomes: 2O2(g) + 4H2O(l) + 8e- 8OH-(aq)3. A subsequent reaction involves the formation of iron hydroxide: 4Fe2+(aq) + 8OH-(aq) 4Fe(OH)2(aq) These steps contribute to the formation of iron oxide, commonly known as rust, and the overall corrosion process of iron. It's important to note that the corrosion mechanisms and reactions can vary based on the specific metal, environment, and conditions involved.
13-05-2025
Sustainability is not just our goal—it’s our responsibility.At SIW, we are committed to leading the steel industry toward a cleaner, smarter future. From reducing carbon emissions and ensuring zero wastewater discharge to integrating AI-driven efficiency and nurturing our team’s growth, every step we take is driven by a clear mission:Achieve Net Zero by 2050.Hear from our Managing Director, Chandrasekaran Srivatsan, on how we’re building a more sustainable tomorrow.hashtag#Sustainability hashtag#NetZero2050 hashtag#GreenSteel hashtag#AIforSustainability hashtag#SIW hashtag#EPD
We are relentless in our pursuit for excellence in product quality and innovation. We take pride in being able to anticipate your needs and provide tailored solutions for each of your requirements. We strive to exceed expectations.