07-08-2023
Surface corrosion and pitting corrosion differ in the following ways: Surface Corrosion: Surface corrosion refers to the corrosion that occurs on the surface of a metal, where the metal surface is not deeply eroded or penetrated by corrosion to the extent that it becomes pitted or significantly damaged. Pitting Corrosion: Pitting corrosion is corrosion that develops on the metal surface over an extended period, causing the metal surface to be deeply eroded and penetrated into the metal substrate. This leads to significant damage to the metal, rendering it unsuitable for use. Corrosion Mechanism:When a metal undergoes oxidation or is subjected to reduction, the corrosion process takes place, resulting in the erosion of the metal. Therefore, the primary goal of corrosion prevention is to inhibit the occurrence of oxidation reactions. The most resistant metals to corrosion are those with the highest positive electrode potentials, such as gold. Platinum, silver, and red gold also possess good resistance to corrosion due to their relatively high positive electrode potentials. On the other hand, other metals are more susceptible to oxidation, meaning they are more likely to corrode easily. An example of a commonly encountered and distinct corrosion process is the formation of rust on iron or the creation of iron oxide. Iron corrodes when there is the presence of oxygen and water. The corrosion process of iron is relatively complex and has unique characteristics. However, it is believed to involve critical steps, including: 1. Oxidation reaction occurs at a specific area on the iron surface, acting as the anode. This can be represented by the equation: Fe(s) Fe2+(aq) + 2e-2. Oxygen is reduced at another area of the iron surface, acting as the cathode. In the presence of water, the equation becomes: 2O2(g) + 4H2O(l) + 8e- 8OH-(aq)3. A subsequent reaction involves the formation of iron hydroxide: 4Fe2+(aq) + 8OH-(aq) 4Fe(OH)2(aq) These steps contribute to the formation of iron oxide, commonly known as rust, and the overall corrosion process of iron. It's important to note that the corrosion mechanisms and reactions can vary based on the specific metal, environment, and conditions involved.
08-06-2022
เหล็กกล้าที่มีส่วนผสมของธาตุคาร์บอนเป็นธาตุหลัก แบ่ง เป็น 3 ประเภท ดังนี้ 1. เหล็กกล้าคาร์บอนต่ำ (Low Carbon Steel) เป็นเหล็กที่มีปริมาณคาร์บอนไม่เกิน 0.25% นอกจากคาร์บอนแล้ว ยังมีธาตุอื่นผสม- อยู่ด้วย เช่น แมงกานีส ซิลิคอน ฟอสฟอรัส และกำมะถัน แต่มีปริมาณน้อยเนื่องจาก หลงเหลือมาจากกระบวนการผลิต เหล็กประเภทนี้ถูกนำไปใช้ในอุตสาหกรรม และใน ชีวิตประจำวันไม่ต่ำกว่า 90% เนื่องจากขึ้นรูปง่าย เชื่อมง่าย และราคาไม่แพง โดยเฉพาะเหล็กแผ่นมีการนำมาใช้งานอย่างกว้างขวาง เช่น ตัวถังรถยนต์ ชิ้นส่วนยานยนต์ต่างๆ กระป๋องบรรจุอาหาร สังกะสีมุงหลังคา เครื่องใช้ในครัวเรือน และในสำนักงาน 2. เหล็กกล้าคาร์บอนปานกลาง (Medium Carbon Steel) เป็นเหล็กที่มีปริมาณคาร์บอน 0.2-0.5% มีความแข็งแรงและความเค้นแรงดึงมากกว่า เหล็กกล้าคาร์บอนต่ำ แต่จะมีความเหนียวน้อยกว่า สามารถนำไปชุบแข็งได้ เหมาะกับ งานทำชิ้นส่วนเครื่องจักรกล รางรถไฟ เฟือง ก้านสูบ ท่อเหล็ก ไขควง เป็นต้น 3. เหล็กกล้าคาร์บอนสูง (High Carbon Steel) เป็นเหล็กที่มีปริมาณคาร์บอน 0.5 - 1.5% มีความแข็งความแข็งแรงและความเค้น- แรงดึงสูง เมื่อชุบแข็งแล้วจะเปราะ เหมาะสำหรับงานที่ทนต่อการสึกหรอ ใช้ในการทำ เครื่องมือ สปริงแหนบ ลูกปืน เป็นต้น สินค้าที่ สยามลวดสามารถผลิตได้นั้น มีเหล็กกล้าคาร์บอนต่ำ หรือ (Low Carbon Steel) 1.ลวดเหล็กคาร์บอนต่ำ หรือที่เรียกว่า (Cold drawn) คือเหล็กที่ผลิตมาจากเหล็กลวดคาร์บอนต่ำ (Low Carbon Wire Rods) โดยผ่านกระบวนการนำเหล็กกล้าคาร์บอนต่ำมา รีดลดขนาดโดยการรีดเย็น จนเป็นผลิตภัณฑ์ลวดเหล็กกล้าคาร์บอนต่ำ มักใช้กับงานผูกเหล็ก ตะปู ตาข่าย และ ทำปลอกเสาเข็ม และสยามลวด นั้นสามารถผลิตได้ตั้งแต่ขนาด 6-12 mm. น้ำหนักต่อม้วนตั้งแต่ 250 kg - 2500 kg 2.เหล็กกล้าคาร์บอนสูง (High Carbon Steel) ที่เรียกว่า ลวดเหล็กกล้าดึงเย็นเสริมคอนกรีตอัดแรง หรือ PC WIRE , PC STRAND นั่นเอง มักใช้กับงานแผ่นพิ้น เสาเข็ม เสาไฟฟ้า หมอนรองรางรถไฟ และคานสะพาน เป็นต้น และสามารถผลิต PC WIRE ได้ตั้งแต่ขนาด 4-9 mm. และ PC STRAND ขนาด 9.3 , 9.5 , 12.7 และ 15.2 mm.
30-08-2024
Why Choose SIW - Testing Service Center for PC Wire and PC Strand Testing?✔️Convenient, Fast, and Cost-Effective✔️ISO/IEC 17025 Certified by NATA (National Association of Testing Authorities, Australia)✔️Modern, High-Efficiency Equipment with Over 99.95% Accuracy✔️Compliant with Standards of Over 70 Countries, Including TIS, ASTM, JIS, and MoreService Information:1. Fatigue Testing Machine-Brand: Zwick Roell, Model: HA500-Testing Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, BS 5896, LNEC E 542, LNEC E 453, ISO 15630 Part 3, TIS 95-2540, TIS 420-2540-PC Wire: Maximum Load Capacity of 500 kN, Supports Sample -Diameters of 5 – 22 mm-PC Strand: Maximum Load Capacity of 500 kN, Supports Sample -Diameters of 5 – 22 mm-Deformed Bar: Maximum Load Capacity of 500 kN, Supports Sample Diameters of 5 – 40 mmRelaxation Testing Machine2. Testing Standards Supported: AS/NZS 4672.1, AS/NZS 4672.2, ASTM A416/A416M, ASTM A421/A421M, ASTM A881, BS 5896, ISO 15630-3, JIS G3536, TIS 95-2540, TIS 420-2540-PC Wire: Maximum Load Capacity of 300 kN, Supports Sample Diameters of 4 – 9 mm-PC Strand: Maximum Load Capacity of 500 kN, Supports Sample Diameters of 9.3 – 18.0 mm Contact Us: >>Click<<
01-05-2023
To achieve continuous development of the compressive strength of concrete, it is necessary to fully hydrate the cement, which is accomplished through curing. Curing is a method that involves controlling and preventing the evaporation of residual water from the reaction. The objective of curing concrete is twofold: 1) to attain maximum strength and durability in the resulting concrete. 2) to regulate temperature and minimize water evaporation to avoid cracking. The following are typical techniques for curing concrete: 1) Regularly spraying water to keep the concrete moist. 2) Applying a plastic cover after spraying water to prevent water from evaporating. 3) Using sacks soaked in water to cover the concrete. 4) Applying a chemical coating to the surface of the concrete. The Siam Industrial Wire (SIW) provides PC WIRE TIS. 95-2540 and PC STRAND TIS. 420-2540, which are the primary components of prestressed concrete production and are acknowledged in over 50 countries worldwide. SIW offers after-sales services to customers, including free calibration of wire pulling machines at their site to ensure that customers can use prestressed wire with confidence. PC Wire: https://www.siw.co.th/th/product-detail/pc-wire PC Strand: https://www.siw.co.th/th/product-detail/pc-strand
18-08-2022
วันที่ 18 สิงหาคม พ.ศ. 2565 บริษัท สยามลวดเหล็กอุตสาหกรรม จำกัด ร่วมส่งมอบตัวอย่างผลิตภัณฑ์ลวดเหล็กกล้า ขนาด 5 มม. และลวดเหล็กกล้าตีเกลียว ขนาด 9.3 มม. (PC Wire และ PC Strand) แก่คณะวิศวกรรมโยธาและวิศวกรรมก่อสร้าง มหาวิทยาลัยเทคโนโลยีราชมงคลตะวันออก วิทยาเขตอุเทนถวาย รวมทั้งสิ้นจำนวน 60 เส้น อีกทั้งยังมีการแนะนำอบรมกระบวนการผลิต เพื่อใช้เป็นสื่อการเรียนการสอนระดับปริญญาตรีและปริญญาโท สยามลวดเหล็กฯ มีความยินดีที่จะส่งเสริมสร้างสรรค์การพัฒนาบุคลากรภาคการศึกษา เพื่อให้เกิดความเข้าใจและชำนาญในวิชาชีพและต่อยอดเป็นแรงงานที่มีคุณภาพในอุตสาหกรรมในอนาคต
05-07-2023
How deep should the pile be drilled to ensure safety?Piles are an essential component used to support and transfer the weight and load of a building to the ground. The load transfer of a pile occurs through the frictional resistance between the pile surface and the surrounding soil or through direct load transfer to the underlying soil or bedrock. The main purpose of using piles is to prevent the building or structure from settling or sinking into the ground. For small-scale buildings, the piles used are generally shorter in length and fewer in number. However, larger buildings may require a greater number of piles or longer piles to transfer the load to deeper layers of soil and bear a higher load capacity. If the pile extends to the level of hard soil, it can directly transfer the load from the building to the hard soil layer. How do piles bear the load?Piles bear the load through two main types of forces: "skin friction" and "end bearing." 1. Skin Friction: This force is generated by the frictional resistance between the pile surface and the surrounding soil. The magnitude of this force depends on the type of soil (each soil type has different skin friction properties) and the characteristics of the pile surface. 2. End Bearing: This force occurs at the pile tip, where the pile rests on a firm soil layer. The magnitude of this force depends on the type of soil, such as the presence of voids between soil particles. Soils with more voids have a lower load-bearing capacity, while compacted sands have a higher load-bearing capacity. In general pile design, for skin friction piles, the focus is on the size and length of the pile to generate sufficient lateral friction to support the applied load. For end bearing piles, the design aims to have the pile sit on a compacted sand layer. Types of piles used in construction can be broadly categorized into three main types based on their manufacturing and usage characteristics: 1. Spun Piles: These piles are produced by spinning concrete in a mold at high speed. This process results in a dense and strong concrete core with embedded steel reinforcement. Spun piles can be driven or drilled and are suitable for high-rise buildings that require strength to withstand wind loads and earthquakes. 2. Bored Piles: Bored piles are constructed by drilling a hole and then placing steel reinforcement and concrete into the drilled hole. They come in various lengths and sizes as specified. Bored piles are suitable for projects that require high strength and load capacity. 3. Prestressed Concrete (PC) Piles: PC piles are manufactured by placing concrete into a mold that contains prestressed steel wires or strands. The concrete is then compressed to enhance its strength. PC piles are used in construction projects that require high strength and durability in various environmental conditions. Siam Wire Industries (SIW) offers PC Wire and PC Strand, which are the primary components used in the production of prestressed concrete piles. SIW has gained recognition in over 50 countries worldwide and provides post-sales services, including on-site wire pulling tests for customers. These services ensure customer confidence in using SIW's prestressed wire products. PC Wire: [Link to SIW's PC Wire product page] (https://www.siw.co.th/en/product-detail/pc-wire) PC Strand: [Link to SIW's PC Strand product page] (https://www.siw.co.en/th/product-detail/pc-strand)
08-06-2022
ที่เราๆท่านๆ รู้จักตะแกรงเหล็กกันดีอยู่แล้ว แต่ทราบหรือไม่ว่านอกจากตะแกรงเหล็ก ที่นำไปใช้ปูพื้นถนน หรืออาคารรวมถึงผนัง Precast แล้ว ตะแกรงเหล็ก ของสยามลวดเหล็ก ก็ยังมี ตะแกรงที่ชุบกัลวาไนซ์ ที่สามารถนำไปปูรอง ฉนวนกันความร้อนใต้หลังคาได้อีกด้วย ซึ่งทางสยามลวดเอง สามารถผลิตเป็นแผ่น ตามขนาดที่ลูกค้าต้องการแล้วนำไปวางใช้งานได้เลย ได้ทั้งความสะดวกสบาย และรวดเร็ว ในการทำงาน แบบนี้งานเสร็จเร็วแน่นอน
01-09-2022
SIW's adds another testing machine to improve the quality of the product before it reaches the end customer. Our lastest source is a Fatigue testing machine from Germany with- a testing capacity of 72 Pcs/Year- 500kN maximum load for diameters from 4 - 30 mm (*Available up size if change the grip)- frequency of120 Hz for PC Wire, PC StrandRebar for standard : LNEC E 452, ISO15630-3, prEN10138 etc.
We are relentless in our pursuit for excellence in product quality and innovation. We take pride in being able to anticipate your needs and provide tailored solutions for each of your requirements. We strive to exceed expectations.